Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37027733

RESUMO

Augmented reality (AR) has shown potential in computer-aided surgery. It allows for the visualization of hidden anatomical structures as well as assists in navigating and locating surgical instruments at the surgical site. Various modalities (devices and/or visualizations) have been used in the literature, but few studies investigated the adequacy/superiority of one modality over the other. For instance, the use of optical see-through (OST) HMDs has not always been scientifically justified. Our goal is to compare various visualization modalities for catheter insertion in external ventricular drain and ventricular shunt procedures. We investigate two AR approaches: (1) 2D approaches consisting of a smartphone and a 2D window visualized through an OST (Microsoft HoloLens 2), and (2) 3D approaches consisting of a fully aligned patient model and a model that is adjacent to the patient and is rotationally aligned using an OST. 32 participants joined this study. For each visualization approach, participants were asked to perform five insertions after which they filled NASA-TLX and SUS forms. Moreover, the position and orientation of the needle with respect to the planning during the insertion task were collected. The results show that participants achieved a better insertion performance significantly under 3D visualizations, and the NASA-TLX and SUS forms reflected the preference of participants for these approaches compared to 2D approaches.

2.
Comput Methods Programs Biomed ; 233: 107453, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36921463

RESUMO

PURPOSE: Selective internal radiation therapy (SIRT) has been proven to be an effective treatment for hepatocellular carcinoma (HCC) patients. In clinical practice, the treatment planning for SIRT using 90Y microspheres requires estimation of the liver-lung shunt fraction (LSF) to avoid radiation pneumonitis. Currently, the manual segmentation method to draw a region of interest (ROI) of the liver and lung in 2D planar imaging of 99mTc-MAA and 3D SPECT/CT images is inconvenient, time-consuming and observer-dependent. In this study, we propose and evaluate a nearly automatic method for LSF quantification using 3D SPECT/CT images, offering improved performance compared with the current manual segmentation method. METHODS: We retrospectively acquired 3D SPECT with non-contrast-enhanced CT images (nCECT) of 60 HCC patients from a SPECT/CT scanning machine, along with the corresponding diagnostic contrast-enhanced CT images (CECT). Our approach for LSF quantification is to use CNN-based methods for liver and lung segmentations in the nCECT image. We first apply 3D ResUnet to coarsely segment the liver. If the liver segmentation contains a large error, we dilate the coarse liver segmentation into the liver mask as a ROI in the nCECT image. Subsequently, non-rigid registration is applied to deform the liver in the CECT image to fit that obtained in the nCECT image. The final liver segmentation is obtained by segmenting the liver in the deformed CECT image using nnU-Net. In addition, the lung segmentations are obtained using 2D ResUnet. Finally, LSF quantitation is performed based on the number of counts in the SPECT image inside the segmentations. Evaluations and Results: To evaluate the liver segmentation accuracy, we used Dice similarity coefficient (DSC), asymmetric surface distance (ASSD), and max surface distance (MSD) and compared the proposed method to five well-known CNN-based methods for liver segmentation. Furthermore, the LSF error obtained by the proposed method was compared to a state-of-the-art method, modified Deepmedic, and the LSF quantifications obtained by manual segmentation. The results show that the proposed method achieved a DSC score for the liver segmentation that is comparable to other state-of-the-art methods, with an average of 0.93, and the highest consistency in segmentation accuracy, yielding a standard deviation of the DSC score of 0.01. The proposed method also obtains the lowest ASSD and MSD scores on average (2.6 mm and 31.5 mm, respectively). Moreover, for the proposed method, a median LSF error of 0.14% is obtained, which is a statically significant improvement to the state-of-the-art-method (p=0.004), and is much smaller than the median error in LSF manual determination by the medical experts using 2D planar image (1.74% and p<0.001). CONCLUSIONS: A method for LSF quantification using 3D SPECT/CT images based on CNNs and non-rigid registration was proposed, evaluated and compared to state-of-the-art techniques. The proposed method can quantitatively determine the LSF with high accuracy and has the potential to be applied in clinical practice.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Estudos Retrospectivos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Pulmão/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
3.
Med Image Anal ; 78: 102422, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35339951

RESUMO

Multiphase CT scanning of the liver is performed for several clinical applications; however, radiation exposure from CT scanning poses a nontrivial cancer risk to the patients. The radiation dose may be reduced by determining the scan range of the subsequent scans by the location of the target of interest in the first scan phase. The purpose of this study is to present and assess an automatic method for determining the scan range for multiphase CT scans. Our strategy is to first apply a CNN-based method for detecting the liver in 2D slices, and to use a liver range search algorithm for detecting the liver range in the scout volume. The target liver scan range for subsequent scans can be obtained by adding safety margins achieved from Gaussian liver motion models to the scan range determined from the scout. Experiments were performed on 657 multiphase CT volumes obtained from multiple hospitals. The experiment shows that the proposed liver detection method can detect the liver in 223 out of a total of 224 3D volumes on average within one second, with mean intersection of union, wall distance and centroid distance of 85.5%, 5.7 mm and 9.7 mm, respectively. In addition, the performance of the proposed liver detection method is comparable to the best of the state-of-the-art 3D liver detectors in the liver detection accuracy while it requires less processing time. Furthermore, we apply the liver scan range generation method on the liver CT images acquired from radiofrequency ablation and Y-90 transarterial radioembolization (selective internal radiation therapy) interventions of 46 patients from two hospitals. The result shows that the automatic scan range generation can significantly reduce the effective radiation dose by an average of 14.5% (2.56 mSv) compared to manual performance by the radiographer from Y-90 transarterial radioembolization, while no statistically significant difference in performance was found with the CT images from intra RFA intervention (p = 0.81). Finally, three radiologists assess both the original and the range-reduced images for evaluating the effect of the range reduction method on their clinical decisions. We conclude that the automatic liver scan range generation method is able to reduce excess radiation compared to the manual performance with a high accuracy and without penalizing the clinical decision.


Assuntos
Processamento de Imagem Assistida por Computador , Radioisótopos de Ítrio , Humanos , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
4.
Med Image Anal ; 61: 101634, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31978856

RESUMO

Percutaneous coronary intervention (PCI) is typically performed with image guidance using X-ray angiograms in which coronary arteries are opacified with X-ray opaque contrast agents. Interventional cardiologists typically navigate instruments using non-contrast-enhanced fluoroscopic images, since higher use of contrast agents increases the risk of kidney failure. When using fluoroscopic images, the interventional cardiologist needs to rely on a mental anatomical reconstruction. This paper reports on the development of a novel dynamic coronary roadmapping approach for improving visual feedback and reducing contrast use during PCI. The approach compensates cardiac and respiratory induced vessel motion by ECG alignment and catheter tip tracking in X-ray fluoroscopy, respectively. In particular, for accurate and robust tracking of the catheter tip, we proposed a new deep learning based Bayesian filtering method that integrates the detection outcome of a convolutional neural network and the motion estimation between frames using a particle filtering framework. The proposed roadmapping and tracking approaches were validated on clinical X-ray images, achieving accurate performance on both catheter tip tracking and dynamic coronary roadmapping experiments. In addition, our approach runs in real-time on a computer with a single GPU and has the potential to be integrated into the clinical workflow of PCI procedures, providing cardiologists with visual guidance during interventions without the need of extra use of contrast agent.


Assuntos
Teorema de Bayes , Aprendizado Profundo , Fluoroscopia/métodos , Intervenção Coronária Percutânea/métodos , Radiografia Intervencionista/métodos , Humanos , Movimento (Física) , Reconhecimento Automatizado de Padrão , Intervenção Coronária Percutânea/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador , Mecânica Respiratória , Técnicas de Imagem de Sincronização Respiratória
5.
PLoS One ; 11(9): e0161600, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27611780

RESUMO

CT-guided percutaneous ablation for liver cancer treatment is a relevant technique for patients not eligible for surgery and with tumors that are inconspicuous on US imaging. The lack of real-time imaging and the use of a limited amount of CT contrast agent make targeting the tumor with the needle challenging. In this study, we evaluate a registration framework that allows the integration of diagnostic pre-operative contrast enhanced CT images and intra-operative non-contrast enhanced CT images to improve image guidance in the intervention. The liver and tumor are segmented in the pre-operative contrast enhanced CT images. Next, the contrast enhanced image is registered to the intra-operative CT images in a two-stage approach. First, the contrast-enhanced diagnostic image is non-rigidly registered to a non-contrast enhanced image that is conventionally acquired at the start of the intervention. In case the initial registration is not sufficiently accurate, a refinement step is applied using non-rigid registration method with a local rigidity term. In the second stage, the intra-operative CT-images that are used to check the needle position, which often consist of only a few slices, are registered rigidly to the intra-operative image that was acquired at the start of the intervention. Subsequently, the diagnostic image is registered to the current intra-operative image, using both transformations, this allows the visualization of the tumor region extracted from pre-operative data in the intra-operative CT images containing needle. The method is evaluated on imaging data of 19 patients at the Erasmus MC. Quantitative evaluation is performed using the Dice metric, mean surface distance of the liver border and corresponding landmarks in the diagnostic and the intra-operative images. The registration of the diagnostic CT image to the initial intra-operative CT image did not require a refinement step in 13 cases. For those cases, the resulting registration had a Dice coefficient for the livers of 91.4%, a mean surface distance of 4.4 mm and a mean distance between corresponding landmarks of 4.7 mm. For the three cases with a refinement step, the registration result significantly improved (p<0.05) compared to the result of the initial non rigid registration method (DICE of 90.3% vs 71.3% and mean surface distance of 5.1 mm vs 11.3 mm and mean distance between corresponding landmark of 6.4 mm vs 10.2 mm). The registration of the preoperative data with the needle image in 16 cases yielded a DICE of 90.1% and a mean surface distance of 5.2 mm. The remaining three cases with DICE smaller than 80% were classified as unsuccessful registration. The results show that this is promising tool for liver image registration in interventional radiology.


Assuntos
Neoplasias Hepáticas/cirurgia , Tomografia Computadorizada por Raios X , Feminino , Humanos , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Fígado/patologia , Fígado/cirurgia , Neoplasias Hepáticas/patologia , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...